<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-03 22-00-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 63 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.8 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 17353 0,1210
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 5,39 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 0,1210 Acquired: 2025/04/03 21.59.39 Total samples: 17353 Equivalent time: 0:14:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 2,7 dBr AVE: 5,39 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2025/04/03 21.59.38) 21.46 21.48 21.50 21.52 21.54 21.56 21.58 0 2 4 6 Pm [dBr]